现场"扫描枪收不到按键"需要区分"按键没到内核"与"到了内核但上层丢了", 以及区分"供电不足/外设取电"与"枪线材问题",补三个可直接复用的工具: - scripts/scan-forensics.ps1:故障当场一键取证(设备/root/uptime、/proc/bus/input/devices、 dmesg usb/hid、App 侧 logcat(WMSScan/WMSPage/UniConsole)、dumpsys input、内核 getevent 抓窗), 并自动输出判据:内核有按键而 App keys=0 -> 上层(Android 分发/WebView);内核无按键 -> 枪/线/供电。 - scripts/power-probe.sh:采样 SARADC / 温度 / 扫码枪是否仍在总线上(RK818 不上报电流, 这是唯一可用的侧面遥测)。 - scripts/power-load-test.sh:固定负载(屏幕最亮 + N 核忙循环)压测并在结束后自动杀掉负载。 实测结论(X9R 12V/2A 24W 临界、音响插平板 USB 口会冲掉 Hub + 枪)见 README 机型注意一节。
31 lines
1.2 KiB
Bash
31 lines
1.2 KiB
Bash
#!/system/bin/sh
|
|
# power-probe.sh - sample the power picture on the RK3288 X9R (needs adb root)
|
|
#
|
|
# Why: on 2026-09-25 the field unit behaved badly on a 12V/2A adapter and fine on 12V/2.5A,
|
|
# which points at input brown-out. The OS has no "rated power" field and the RK818 driver
|
|
# reports 0mA for every rail, so the only usable telemetry is:
|
|
# - SARADC channels (ff100000.saradc, 10-bit, 1.7578125 mV/LSB)
|
|
# - SoC / GPU thermal
|
|
# - whether the USB scanner is still enumerated (brown-out can drop the HID device)
|
|
# Run it once on each adapter and compare (min/max/mean + gun=0 count).
|
|
#
|
|
# usage: pwr_sample.sh [samples] [outfile] (0.5 s per sample)
|
|
N=${1:-120}
|
|
OUT=${2:-/data/local/tmp/pwr_sample.txt}
|
|
DEV=/sys/bus/iio/devices/iio:device0
|
|
i=0
|
|
: > "$OUT"
|
|
while [ "$i" -lt "$N" ]; do
|
|
u=$(cat /proc/uptime); u=${u%% *}
|
|
a0=$(cat $DEV/in_voltage0_raw 2>/dev/null)
|
|
a1=$(cat $DEV/in_voltage1_raw 2>/dev/null)
|
|
a2=$(cat $DEV/in_voltage2_raw 2>/dev/null)
|
|
t0=$(cat /sys/class/thermal/thermal_zone0/temp 2>/dev/null)
|
|
t1=$(cat /sys/class/thermal/thermal_zone1/temp 2>/dev/null)
|
|
gun=$(grep -c Newtologic /proc/bus/input/devices 2>/dev/null)
|
|
echo "$u $a0 $a1 $a2 $t0 $t1 $gun" >> "$OUT"
|
|
i=$((i + 1))
|
|
sleep 0.5
|
|
done
|
|
echo "done $N samples -> $OUT"
|